<LOGO>
FM Transmitter Measurement Report
Created: 2026-05-01 08-39-20
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 4/5, 37 dBuV SANDELS
Pilot RDS Phase Difference
6.0 kHz 4.7 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
12 kHz 65 kHz 3328 0,3005
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
3,6 dBr 5,20 dBr 5,9 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
92.0, 94.7, 106.4, 107.5 MHz -
FM Scope Max at: 65 kHz MIN: 12 kHz % above 76 kHz: 0,3005 Acquired: 2026/05/01 8.38.16 Total samples: 3328 Equivalent time: 0:02:46 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 50 100 150
FM Scope MAX: 5,9 dBr MIN: 3,6 dBr AVE: 5,20 dBr % above 12,2 dBr: 0,0 Last value: 5,0 dBr (2026/05/01 8.38.16) 08.24 08.26 08.28 08.30 08.32 08.34 08.36 08.38 0 2 4 6 Pm [dBr]